Download Data Sheet
Approval: ATEX II 1/2G Ex ia IIC T6
Output; Operating: 4-20mA HART; inside + LCD
Housing; Cover Sealing; Cable Entry: T14 Alu IP66/67 NEMA6P; EPDM;
M20 gland,T14 = side cover(Ex d > M20 thread)
Sensor Range; Sensor Overload Limit: 700bar/70MPa/10500psi
gauge;1050bar/105MPa/15750psi
Calibration; Unit: Sensor range; mbar/bar
Membrane Material: 316L
Process Connection: Thread ANSI MNPT1/2 hole, 316L
Fill Fluid: Silicone oil
Additional Option 2: Mounting bracket, wall/pipe, 316L